MIL-STD-868B CHANGE I
SUMMARY OF CHANGE 1 MODIFICATIONS
The following detail requirement of MIL-STD-8688 has been revised, paragraph
5.4.5.l.c:
New Requirement: Operate at 60° to 75°F, 3 to 6 amps per square inch anodic for 45 to
90 seconds.
Old Requirement: Operate at 60° to 75°F, 3 to 6 amps per square foot anodic for 45 to
90 seconds.