TT-C-490F
examined using the same acceptance criteria noted for the accelerated corrosion test in 3.6.6.2 of this specification, unless an accelerated corrosion test such as the sulfur dioxide salt spray test specified in ASTM G85 is specified in the contract. In that case, that test protocol as indicated in the contract should be used to qualify the pretreatment/primer. MIL-DTL-5541 requires some testing other than that covered in this document for aluminum and aluminum alloys.
6.1.4 Method of application. New design documents, engineering drawings and ordering data should indicate the type of coating required, cleaning requirements and methods of application when practicable.
6.1.5 Application conditions. The contractor should be cognizant of the environmental controls necessary so as not to apply any coating outside the coating manufacturer's recommendations. Organic coatings should not be applied when the surface temperature, air temperature, or relative humidity would cause a negative effect on the application and subsequent function of the applied coating. When surface temperature or air temperature are < 5 °F above dew point, the coating is adversely affected. At relative humidity in excess of 50%, a dew point calculation may be necessary to avoid the formation of moisture on the substrate to be coated. Limits on humidity during application of a coating should be determined in the guidelines set forth by the manufacturer of the coating (see table III).
TABLE III. Dew Point.
AMBIENT AIR TEMPERATURE (°F) |
||||||||||||
20 |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
120 |
||
% RELATIVE HUMIDITY |
90 |
18 |
28 |
37 |
47 |
57 |
67 |
77 |
87 |
97 |
107 |
117 |
85 |
17 |
26 |
36 |
45 |
55 |
65 |
75 |
84 |
95 |
104 |
113 |
|
80 |
16 |
25 |
34 |
44 |
54 |
63 |
73 |
82 |
93 |
102 |
110 |
|
75 |
15 |
24 |
33 |
42 |
52 |
62 |
71 |
80 |
91 |
100 |
108 |
|
70 |
13 |
22 |
31 |
40 |
50 |
60 |
68 |
78 |
88 |
96 |
105 |
|
65 |
12 |
20 |
29 |
38 |
47 |
57 |
66 |
76 |
85 |
93 |
103 |
|
60 |
11 |
19 |
27 |
36 |
45 |
55 |
64 |
73 |
83 |
92 |
101 |
|
55 |
9 |
17 |
25 |
34 |
43 |
53 |
61 |
70 |
80 |
89 |
98 |
|
50 |
6 |
15 |
23 |
31 |
40 |
50 |
59 |
67 |
77 |
86 |
94 |
|
45 |
4 |
13 |
21 |
29 |
37 |
47 |
56 |
64 |
73 |
82 |
91 |
|
40 |
1 |
11 |
18 |
26 |
35 |
43 |
52 |
61 |
69 |
78 |
87 |
|
35 |
·2 |
8 |
16 |
23 |
31 |
40 |
48 |
57 |
65 |
74 |
83 |
|
30 |
·6 |
4 |
13 |
20 |
28 |
36 |
44 |
52 |
61 |
69 |
77 |
Note 1: Dew point is the temperature at which moisture will condense on the surface.
No organic coatings should be applied unless the surface temperature of the substrate is a minimum of 5 °F above the dew point at the point of application.
21