MIL-STD-186F (MI)
TABLE II. Surface treatments - Continued.
Code No. |
Treatment |
234 235 |
Water-Repellant Preservative (WRP) Treatment. Apply one liberal coat of WRP solution to the wood surfaces. The solution shall contain copper naphthenate, boiled linseed oil or exterior- grade varnish, paraffin, and solvent. Where practical, apply the solution by immersion for not less than 3 minutes. Otherwise, brushing or low pressure spraying is acceptable. Allow the treated wood to air dry or kiln dry before it is painted. Phosphoric acid anodize (SAE ARP 1524) (preferred treatment for critical aluminum adhesively bonded joints). |