5.6 Galvanic corrosion. Dissimilar metals as defined in table III shall not be used in intimate contact unless suitably protected against electrolytic corrosion. Because of the seriousness of galvanic corrosion, every effort shall be made to avoid the use of dissimilar metals, to exclude moisture or other electrolyte from the system, and to protect metal surfaces in the contact area. Where it is necessary that metals not shown as "compatible" in table III
be assembled, applicable measures such as those given in table IV or MIL-F-7179 shall be used to prevent corrosion. Special attention is called to the following: